康明斯发电机组600-2250KVA |
|
| 产品参数: |
|
|
发电机型号 |
发动机型号 |
50Hz
|
重量(kg)
|
尺寸(mm)
|
|
KVA |
KW |
Wet |
Dry |
L |
W |
H |
50Hz |
|
BCC630P(S) |
VTA28G5 |
632 |
504 |
6000 |
5750 |
3705 |
1636 |
1986 |
140 |
BCC670S(S) |
VTA28G5 |
670 |
536 |
6000 |
5750 |
3705 |
1636 |
1986 |
154 |
BCC800P(S) |
QST30G2 |
797 |
638 |
6900 |
6580 |
4174 |
1636 |
2095 |
168 |
BCC880S(S) |
QST30G2 |
879 |
703 |
6900 |
6580 |
4174 |
1636 |
2095 |
187 |
BCCl010P(S) |
QST30G4 |
1000 |
800 |
7600 |
7100 |
4174 |
1636 |
2095 |
202 |
BCCll00S(S) |
QST30G4 |
1100 |
880 |
7600 |
7100 |
4174 |
1636 |
2095 |
224 |
BCCl020P(S) |
KTA38G5 |
1019 |
815 |
8900 |
8480 |
4457 |
1886 |
2482 |
209 |
BCCll30S(S) |
KTA38G5 |
1131 |
905 |
8900 |
8480 |
4457 |
1886 |
2482 |
228 |
BCCl250P(S) |
KTA50G3 |
1276 |
1021 |
10900 |
10410 |
5122 |
1886 |
2399 |
261 |
BCCl430S(S) |
KTA50G3 |
1437 |
1150 |
10900 |
10740 |
5122 |
1886 |
2399 |
293 |
BCCl500P(S) |
KTA50G8 |
1500 |
1200 |
12400 |
11620 |
5752 |
2136 |
2489 |
310 |
Bccl670S(S) |
KTA50G8 |
1676 |
1341 |
12400 |
11620 |
5752 |
2136 |
2489 |
345 |
BCCl700P(S) |
QSK60G2 |
1710 |
1368 |
16000 |
15090 |
5994 |
2288 |
3046 |
337 |
BCCl920S(S) |
QSK60G2 |
1920 |
1536 |
16000 |
15090 |
5994 |
2288 |
3046 |
373 |
BCC2000P(S) |
QSK60G4 |
2000 |
1600 |
16000 |
15090 |
5994 |
2288 |
3046 |
394 |
BCC2250S(S) |
QSK60G4 |
2250 |
1800 |
16000 |
15090 |
5994 |
2288 |
3046 |
437 |
|
| |
| 注:三相 380V/150Hz |
| |
| 详细说明 |
|
1、功率说明
◆额定功率(机组附有“P”标识)
所有功率适用于持续功率(在可变动力系统下,对通常一年内运行时间不加限的运行),
同时所有机组均可在运行12小时后供给1小时备用功率。
◆备用功率(机组附有“S”标识),备用功率为额定功率的110%。
备用功率在主要电力系统瘫痪时进行供电,每年最多可达500小时,不允许超时限工作。
2 “额定值”的定义(额定值的测定环境)
◆“发电机组输出功率适用于380V-416V电压范围(三相均衡发电),外界温度为
25℃-40℃,海拔100m-1000m,外界大气压强为0.8pf。
◆所有数据均符台IS08528、BS5514、IS03046、DIN6271标准。
◆总重=机重+润滑油重+冷却剂重
净重=机重=润滑油重
◆发电机组图示,包括额外附件在内,说明书及设计如有变动,另行通知。
|
| |
康明斯发电机组56-1000KVA |
|
| 产品参数: |
|
机组型号 |
标定功率 |
输出电流 |
柴油机型号 |
燃油率
|
最大功率 |
汽缸数 |
缸径/行程 |
机组尺寸(mm) |
净重 |
KVA |
KW |
A |
g/kw.h |
KW |
mm |
L |
W |
H |
kg |
|
SBC56P |
56 |
45 |
79 |
4BTA3.9-G |
208 |
55 |
4 |
102/120 |
1800 |
700 |
1300 |
860 |
SBC100P |
100 |
80 |
144 |
6BTA5.9-G |
206 |
102 |
6 |
102/120 |
2270 |
800 |
1300 |
1150 |
SBC125P |
125 |
100 |
180 |
6BTAA5.9-G |
206 |
132 |
6 |
102/120 |
2270 |
820 |
1300 |
1200 |
SBC150P |
150 |
120 |
216 |
6CTA8.3-G |
205 |
180 |
6 |
114/135 |
2510 |
820 |
1300 |
1600 |
SBC200P |
200 |
160 |
288 |
6CTAA8.3-G |
205 |
207 |
6 |
114/135 |
2510 |
820 |
1300 |
2100 |
SBC250P |
250 |
200 |
361 |
NTA855-G1 |
203 |
265 |
6 |
140/152 |
3155 |
1050 |
1540 |
3400 |
SBC312P |
312 |
250 |
450 |
NTA855-G2 |
202 |
321 |
6 |
140/152 |
3155 |
1050 |
1540 |
3650 |
SBC350P |
350 |
280 |
499 |
NTA855-G4 |
202 |
351 |
6 |
140/152 |
3155 |
1050 |
1540 |
4495 |
SBC375P |
375 |
300 |
541 |
NTA855-G7 |
201 |
377 |
6 |
140/152 |
3155 |
1050 |
1540 |
4495 |
SBC375-1P |
375 |
300 |
541 |
KTA19-G2 |
206 |
360 |
6 |
159/159 |
3440 |
1300 |
1915 |
4630 |
SBC450P |
450 |
360 |
650 |
KTA19-G3 |
201 |
436 |
6 |
159/159 |
3440 |
1300 |
1915 |
4850 |
SBC500P |
500 |
400 |
722 |
KTA19-G4 |
200 |
492 |
6 |
159/159 |
3445 |
1300 |
1920 |
4900 |
SBC600P |
600 |
480 |
874 |
KTA19-G6 |
199 |
570 |
6 |
159/159 |
3445 |
1300 |
1920 |
5010 |
SBC625P |
625 |
500 |
902 |
KTA38-G1 |
196 |
591 |
12 |
159/159 |
4336 |
1900 |
2310 |
7300 |
SBC750P |
750 |
600 |
1082 |
KTA38-G2 |
196 |
731 |
12 |
159/159 |
4525 |
1900 |
2310 |
8370 |
SBC1000P |
1000 |
800 |
1440 |
KTA38-G5 |
197 |
970 |
12 |
159/159 |
4525 |
1900 |
2310 |
8900 |
|
| |
| 详细说明 |
|
1、功率说明
◆额定功率(机组附有“P”标识)
所有功率适用于持续功率(在可变动力系统下,对通常一年内运行时间不加限的运行),
同时所有机组均可在运行12小时后供给1小时备用功率。
◆备用功率(机组附有“S”标识),备用功率为额定功率的110%。
备用功率在主要电力系统瘫痪时进行供电,每年最多可达500小时,不允许超时限工作。
2 “额定值”的定义(额定值的测定环境)
◆“发电机组输出功率适用于380V-416V电压范围(三相均衡发电),外界温度为
25℃-40℃,海拔100m-1000m,外界大气压强为0.8pf。
◆所有数据均符台IS08528、BS5514、IS03046、DIN6271标准。
◆总重=机重+润滑油重+冷却剂重
净重=机重=润滑油重
◆发电机组图示,包括额外附件在内,说明书及设计如有变动,另行通知。 |